my klicky was running flawlessly without [z_calibration] enabled, seems like my homing overide didnt work well with that.
just like the tittle above, i've changed the endstop pin to the segsbolt endstop too since probe:virtual endstop wont work with [z_calibration] enabled.
[z_calibration]
nozzle_xy_position: 142,241 #default from home_xy_position of safe_z_home
# A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the z endstop.
switch_xy_position: 135,205 #optional when switch_xy_offsets is used
# A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on
# the z endstop.
bed_xy_position: 115,115 #default from zero_reference_position (or relative_reference_index) of bed_mesh
# A X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center
# point) is probed. These coordinates are adjusted by the
# probe's X and Y offsets. The default is the zero_reference_position which
# replaces the deprecated relative_reference_index
# of the configured bed_mesh, if configured. It's possible to change the zero
# reference position at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z.
wiggle_xy_offsets: 0,0
# After probing the nozzle and retracting, move x some distance away and
# back. Useful to prevent the z endstop pin sticking to the nozzle and
# being pulled out of the assembly. Can be negative. Defaults to zero to
# disable it. Can be combined in x and y to move diagonally. Be careful
# to not move your nozzle out of range!
switch_offset: 0.5
# The trigger point offset of the used mag-probe switch.
# A larger value will position the nozzle closer to the bed.
# This must be determined manually. More on this later
# in this section..
offset_margins: -1.0,1.0
# The minimum and maximum margins allowed for the calculated offset.
# If the offset is outside these values, it will stop!
# The margin can be defined as "min,max" e.g. "-0.5,1.5" or by just one
# value e.g. "1.0" which translates to "-1.0,1.0" (which is also the default).
safe_z_height: 10 #default is 2 * z_offset from the "probe:z_offset" section
# The absolute z position in mm to move to before moving to the next
# position. The default is two times the z_offset from the probe's
# configuration. The minimum safe z height is 3mm.
position_min: 10 #default from "stepper_z:position_min" section.
# Minimum valid distance (in mm) used for probing move. The
# default is from the Z rail configuration.
speed: 50
# The moving speed in X and Y. The default is 50 mm/s.
start_gcode:
ATTACH_PROBE
before_switch_gcode:
G90
G1 Z10 F1200 # Lift nozzle before moving
ATTACH_PROBE # Ensure Klicky is attached
end_gcode:
G90
G1 Z10 F1200 # Lift nozzle after calibration
DOCK_PROBE # Dock Klicky after use
my klicky was running flawlessly without [z_calibration] enabled, seems like my homing overide didnt work well with that.
just like the tittle above, i've changed the endstop pin to the segsbolt endstop too since probe:virtual endstop wont work with [z_calibration] enabled.
there are my [z_calibration] config: